Active comp Real Time Power Factor Correction System (RTPFC)
Active comp Real Time Power Factor Correction System
- Possible to design Hybrid Solution for P.F. Correction with Active Harmonic Filtration with modular AHF Units.
- Front optical port for Controller setting, downloading data through Software / Mobile Application
- Additional Systems can be added easily with existing System by using Master / Slave configuration
- Suitable for use on both Utility & Genset supply with Dual P.F. mode
- Extreme Long Life Expectancy of System
- Integral Power, Harmonic & Waveform Analyzer with Data Logger
- Data sending by SMS and Email for Alarm Conditions
Description
Features of Active comp Real Time Power Factor Correction System
- Suitable for Real Time Power Factor Correction & Harmonic Filtration using Thyristor Modules
- Suitable for PF Compensation of Networks having Dynamic loads like Welding and other Sensitive Loads like VFDs, electronic loads, Automation Loads
- Fast Compensation & Unlimited Number of Transient Free Operations
- Available for Network Voltage of 380V, 415V, 480V, 690V, 750V (50/60Hz)
- Available in both Balanced and Unbalanced configuration
- Saves Energy, Mitigate Harmonics & reduce electric billing
- Suitable for both Tuned and Detuned application
Applications
- Automobile Industries
- Motor Start-up
- Plastic Injection Factories
- Harbor Cranes
- Sensitive Loads
- Metals & Steel industries
- Cement Plants
- Textile Industries
- Generators
- Data & Medical Centers
- High Rise/Office Buildings
- Educational Institutions
- Recreational Facilities
- Local Power Generation
- Welding Application
Technical Specification
Design | Standardized bolted Modular Sheet Steel Enclosures-Non compartmentalized / Compartmentalized |
Enclosure Finish | Epoxy powder coated, in grey (RAL 7035) structure finish |
Rated Voltage | 415V-440V/50Hz (Design available for 380V, 480V, 690V, 750V – 50/60Hz) |
Output Rating | : 50 to 5000 Kvar |
Capacitors | : DUCA POWER Super Heavy Duty Series used are rated at 525V, 690V & 800V, 50/60Hz as per network voltage |
Reactors | : H-Class, 5.6%, 6%, 7%, 12.5%, 14% or any other Tuning / Detuning rating on request |
Incoming/Outgoing | MCCB / ACB as Incomer and HRC Fuses for backup protection (other combinations on request) |
Dimension | Contact our Sales Office |
Ambient Temperature | 50°C max short time |
40°C average in 24 hours | |
35°C annual average | |
-10°C low limit | |
Protection class | IP 40 |
Unbalanced Activcomp System | : For Unbalanced Activcomp System ratings & specifications Contact our Sales Office |