Active comp Real Time Power Factor Correction System (RTPFC)

Active comp Real Time Power Factor Correction System

  • Possible to design Hybrid Solution for P.F. Correction with Active Harmonic Filtration with modular AHF Units.
  • Front optical port for Controller setting, downloading data through Software / Mobile Application
  • Additional Systems can be added easily with existing System by using Master / Slave configuration
  • Suitable for use on both Utility & Genset supply with Dual P.F. mode
  • Extreme Long Life Expectancy of System
  • Integral Power, Harmonic & Waveform Analyzer with Data Logger
  • Data sending by SMS and Email for Alarm Conditions

Description

Features of Active comp Real Time Power Factor Correction System

  • Suitable for Real Time Power Factor Correction & Harmonic Filtration using Thyristor Modules
  • Suitable for PF Compensation of Networks having Dynamic loads like Welding and other Sensitive Loads like VFDs, electronic loads, Automation Loads
  • Fast Compensation & Unlimited Number of Transient Free Operations
  • Available for Network Voltage of 380V, 415V, 480V, 690V, 750V (50/60Hz)
  • Available in both Balanced and Unbalanced configuration
  • Saves Energy, Mitigate Harmonics & reduce electric billing
  • Suitable for both Tuned and Detuned application

Applications

  • Automobile Industries
  • Motor Start-up
  • Plastic Injection Factories
  • Harbor Cranes
  • Sensitive Loads
  • Metals & Steel industries
  • Cement Plants
  • Textile Industries
  • Generators
  • Data & Medical Centers
  • High Rise/Office Buildings
  • Educational Institutions
  • Recreational Facilities
  • Local Power Generation
  • Welding Application

Technical Specification

Design Standardized bolted Modular Sheet Steel Enclosures-Non compartmentalized / Compartmentalized
Enclosure Finish Epoxy powder coated, in grey (RAL 7035) structure finish
Rated Voltage 415V-440V/50Hz (Design available for 380V, 480V, 690V, 750V – 50/60Hz)
Output Rating : 50 to 5000 Kvar
Capacitors : DUCA POWER Super Heavy Duty Series used are rated at 525V, 690V & 800V, 50/60Hz as per network voltage
Reactors : H-Class, 5.6%, 6%, 7%, 12.5%, 14% or any other Tuning / Detuning rating on request
Incoming/Outgoing MCCB / ACB as Incomer and HRC Fuses for backup protection (other combinations on request)
Dimension Contact our Sales Office
Ambient Temperature 50°C max short time
40°C average in 24 hours
35°C annual average
-10°C low limit
Protection class IP 40
Unbalanced Activcomp System : For Unbalanced Activcomp System ratings & specifications Contact our Sales Office