| Technical Characteristics |
|
|
Auxiliary supply
|
Rated voltage Us
Operating limit
Frequency
Maximum consumption / dissipation
Immunity time for microbreakings
|
180-260VAC
180-260VAC
45-65Hz
10VA / 4W
20ms
|
| Voltage Inputs
|
Max. rated voltage Ue
UL rating
Measuring range
Frequency range
Measuring method
Measuring input impedeance
Wiring mode
|
690VAC phase-phase 400VAC phase-neutral
600VAC phase-phase 347VAC phase-neutral
20-830VAC phase-phase; 10-480VAC phase-neutral
45-65Hz
True RMS
<1.1MW phase-phase;>57k
W phase-neutral
Single phase, two-phase, three-phase systems with or
without neutral
|
| Current Inputs
|
Rated Current Le
Measuring range
UL rating
Measuring method
Overload capacity
Overload peak
Power consumption
|
5A
0.02-6A
Supplied by an external transformer (low voltage)-Max 5A
True RMS
+20% le from external CT with 5A secondary
50A for 1 second
<0.3VA
|
| Measuring
Accuracy
|
Measuring conditions
|
Tempertature+23°C ±1°C
Relative Humidity≤60%RH
Voltage 0.2-1.2 Ue Current 0.2-1.2 le
|
|
Voltage and current
|
±1digit
|
|
Frequency and Harmonic Distortion
|
±1digit
|
|
Apparent power
|
±0.15% full scale ±1digit
|
Active power
|
±0.25% full scale ±1digit ( cos φ 0.7-1)/±0.30% full
scale±digit(cosφ
0.3-0.7)
|
Reactive power
|
±0.25% full scale ±1digit ( sine φ 0.7-1)/±0.30% full
scale±digit(sineφ
0.3-0.7)
|
Energy
|
± 1digit Class-1/class-0.5 (IEC/EN
61036 and 61268)
|
| Additional Errors
|
| Relative Humidity
|
±1 digit 60% to 90% R.H |
|
Temperature
|
±1 digit -20°C to + 60°C |
|
Acquisition Time
|
|
|
Sampling interval with P.06 AUT and P.07 ON
|
≤130ms |
|
Sampling interval with .06 50 or 60 Hz & P.07 ON
|
≤80ms |
|
Sampling interval with P.06 AUT and P.07 OFF
|
≤110ms |
|
Sampling interval with P.06 50 or 60 Hz & P.07
OFF
|
≤60ms |
|
Display update interval
|
300ms |
|
|
|
| Communication Ports
|
| RS485 serial interface |
Opto-isolated,with programmable baud rate
|
| AC Insulation Voltage
|
Auxiliary supply
Voltage inputs
Current inputs
Serial link |
4KV
1.5KV
1.5KV
1.5KV
|
| Operating Ambient
Conditions |
Operating temperature
Storage temperature
Relative Humidity
Maximum Pollution degree |
-20° to +60°C
-30° to
+70°C
<90%
2 |
| Connections |
Type of terminal
Cable cross section (min-max )
Tightening torque
RS485 interface |
Plug-in
0.2-2.5 mmsq.(24-12 AWG)
0.5Nm (4.5 lbin)
Plug in type |
|
| Housing |
| Material |
Self extinguishing ul94 v-0 black Noryl |
|
Version |
Flush-mount DIN 43700 |
|
Dimensions W x H x D |
96 x 96 x 91mm |
|
Panel cutout dimensions |
91 x 91mm |
|
Protection degree |
lp54 on front lp54 with transparent cover lp20
housing and terminals |
|
Weight |
0.47kg |